8
8
8
4
1rem
1rem
1rem
1rem
rt-dark-800
headline-3
false
Application Note Name
false
basicInfoTitle
24
12
12
12
rt-dark-300
applicationNoteInfo
12
12
12
12
left
buttonDownload
text-with-icon
secondary
i18n(button-item.download.button-label)
i18n(button-item.download.button-link)
_self
false
btnAllApplicationNote
text-with-icon
secondary
i18n(button-item.all-application-note.button-label)
i18n(button-item.all-application-note.button-link)
_self
false
withLine
2rem
2rem
2rem
0
<div class=WordSection1> <h1>DCR Temperature Compensation</h1> <p><br><br></p> <h2 id="__Bookmark__0">Abstract</h2> <p>The DCR current sensing technique provides a good solution to get the inductor current information due to its lossless characteristic. However, the inductor DCR value may vary with the temperature, since copper is a positive temperature coefficient. Therefore, the temperature variation on the DCR value may cause the controller to sense a false current signal. To cancel the temperature effect, a DCR temperature network is usually added in the current sense loop. This application note will introduce the basic concept and the implementation methods for DCR temperature compensation.</p> <p class=MsoNormal><br> <br> </p> <h2 id="__Bookmark__1">1. Why We Need a DCR Temperature Compensation Network</h2> <p>Figure 1 shows the DCR current sensing network. When the time constants are equal, that is, C<sub>x</sub>R<sub>x</sub> = L / DCR, the V<sub>CX</sub> voltage can be used to obtain the inductor current signal as shown in (1). However, the DCR value will increase proportionally with the temperature, which is described in (2) where the parameter TC<sub>DCR</sub> is the temperature coefficient of the copper with a positive value. When the circuit operates in the heavy load condition, the inductor’s temperature will increase as well. That will make the regulator falsely detect the load current level and provide the inaccuracy current reporting information because the DCR value varies under different temperature conditions. Besides, the output voltage could not reach to its desired value and then violate the load-line specs while adaptive voltage position droop for Vcore applications is required. Therefore, a temperature compensation network is used to solve the problem.</p> <p class=MsoNormal><a class="fancybox" href="/content/dam/richtek-eds/resources/application-notes/an026/html-images-en/image001_en.jpg" ><img width=321 height=46 id="圖片 1" src="/content/dam/richtek-eds/resources/application-notes/an026/html-images-en/image001_en.jpg" alt="Technical Document Image Preview"></a></p> <p class=MsoNormal><a class="fancybox" href="/content/dam/richtek-eds/resources/application-notes/an026/html-images-en/image002_en.jpg" ><img width=234 height=138 id="圖片 3" src="/content/dam/richtek-eds/resources/application-notes/an026/html-images-en/image002_en.jpg" alt="Technical Document Image Preview"></a></p> <p class=MsoNormal>Figure 1. DCR current sensing network</p> <p class=MsoNormal><br> <br> </p> <h2 id="__Bookmark__2">2. Topologies of DCR Temperature Compensation</h2> <p>The DCR temperature compensation network aims the DCR value to be invariant with the temperature, hence the V<sub>CX</sub> voltage can be only dependent on the inductor current. Since the DCR is a resistor with the positive temperature coefficient, a resistor network with the negative temperature coefficient should be inserted in the current sensing loop to compensate the DCR variations due to temperatures. When there are Y temperature points need to be compensated, the compensation network requires Y resistors and one negative temperature coefficient (NTC) thermistor to cancel out the DCR variations under these Y temperature points. However, according to the current sensing topologies, the DCR temperature compensation network should be implemented in the proper place. Figure 2 and Figure 3 are respectively shown the implementation of the temperature compensation network in the sum current and differential sensing topologies. Therefore, the sum current sensing topology demonstrates the compensation network which is used to compensate three temperature points, and the differential sensing topology demonstrates the compensation network for two temperature points. Equations (3) and (4) are used to describe the design criterions for these two current sensing topologies.</p> <p class=MsoNormal><a class="fancybox" href="/content/dam/richtek-eds/resources/application-notes/an026/html-images-en/image003_en.jpg" ><img width=344 height=87 id="圖片 8" src="/content/dam/richtek-eds/resources/application-notes/an026/html-images-en/image003_en.jpg" alt="Technical Document Image Preview"></a></p> <p class=MsoNormal><a class="fancybox" href="/content/dam/richtek-eds/resources/application-notes/an026/html-images-en/image004_en.jpg" ><img width=658 height=470 id="圖片 9" src="/content/dam/richtek-eds/resources/application-notes/an026/html-images-en/image004_en.jpg" alt="Technical Document Image Preview"></a></p> <p class=MsoNormal>Figure 2. DCR temperature compensation network in sum current sensing topology </p> <p class=MsoNormal><a class="fancybox" href="/content/dam/richtek-eds/resources/application-notes/an026/html-images-en/image005_en.jpg" ><img width=672 height=547 id="圖片 10" src="/content/dam/richtek-eds/resources/application-notes/an026/html-images-en/image005_en.jpg" alt="Technical Document Image Preview"></a></p> <p class=MsoNormal>Figure 3. DCR temperature compensation network in differential current sensing topology</p> <p class=MsoNormal><br> <br> </p> <h2 id="__Bookmark__3">3. Derivation of DCR Temperature Compensation Network</h2> <p>In this section, the sum current sensing topology will be used as an example to derive the temperature compensation network. As shown in (3), the load current information can be correctly acquired through the V<sub>sum</sub> voltage with a proper gain. This gain can be expressed as the ratio between R<sub>sum</sub> and (R<sub>x</sub>+R<sub>s</sub>) and be shown in (5). For example, this ratio in RT8893 must set as 4 for the proper operation. </p> <p><a class="fancybox" href="/content/dam/richtek-eds/resources/application-notes/an026/html-images-en/image006_en.jpg" ><img width=233 height=41 id="圖片 12" src="/content/dam/richtek-eds/resources/application-notes/an026/html-images-en/image006_en.jpg" alt="Technical Document Image Preview"></a></p> <p>However, in order to cancel the temperature effect on the DCR, a NTC thermistor is inserted in the R<sub>sum</sub> network to make the V<sub>sum</sub> voltage be invariant with the temperature. The relationship between NTC and temperature is shown in (6), where β is the temperature coefficient of the NTC thermistor and is varied with different NTC thermistor. </p> <p><a class="fancybox" href="/content/dam/richtek-eds/resources/application-notes/an026/html-images-en/image007_en.jpg" ><img width=286 height=37 id="圖片 13" src="/content/dam/richtek-eds/resources/application-notes/an026/html-images-en/image007_en.jpg" alt="Technical Document Image Preview"></a></p> <p>If there are three temperature points (TL, TR, TH) need to be compensated, the V<sub>sum</sub> voltage at these three temperature points should be set equally and the results can then be shown in (7). R<sub>sum</sub>(T) is the equivalent resistor of the thermal compensation network with a NTC thermistor and can be obtained as (8).</p> <p><a class="fancybox" href="/content/dam/richtek-eds/resources/application-notes/an026/html-images-en/image008_en.jpg" ><img width=348 height=96 id="圖片 14" src="/content/dam/richtek-eds/resources/application-notes/an026/html-images-en/image008_en.jpg" alt="Technical Document Image Preview"></a></p> <p>Therefore, with above equations, the parameters of the R<sub>sum</sub> network can be accordingly found out as (9), (10), and (11). Please see Appendix I for further details.</p> <p class=MsoNormal><a class="fancybox" href="/content/dam/richtek-eds/resources/application-notes/an026/html-images-en/image009_en.jpg" ><img width=348 height=123 id="圖片 15" src="/content/dam/richtek-eds/resources/application-notes/an026/html-images-en/image009_en.jpg" alt="Technical Document Image Preview"></a></p> <p class=MsoNormal><a class="fancybox" href="/content/dam/richtek-eds/resources/application-notes/an026/html-images-en/image010_en.jpg" ><img width=566 height=77 id="圖片 16" src="/content/dam/richtek-eds/resources/application-notes/an026/html-images-en/image010_en.jpg" alt="Technical Document Image Preview"></a></p> <p class=MsoNormal>where </p> <p>After implementing the temperature compensation, the V<sub>SUM</sub> error at these three temperature points (ex: 20°C, 60°C, and 100°C) should be zero as shown in Figure 4.</p> <p class=MsoNormal><a class="fancybox" href="/content/dam/richtek-eds/resources/application-notes/an026/html-images-en/image011_en.jpg" ><img width=680 height=455 id="圖片 11" src="/content/dam/richtek-eds/resources/application-notes/an026/html-images-en/image011_en.jpg" alt="Technical Document Image Preview"></a></p> <p class=MsoNormal>Figure 4. V<sub>sum</sub> error after DCR temperature compensation </p> <p class=MsoNormal><br> <br> </p> <h2 id="__Bookmark__4">4. Design Example of DCR Thermal Compensation Network</h2> <p>The following design approach will use the sum current sensing topology with RT8893 as an example, and the specifications are designed to meet the Intel VR12.5 requirements.</p> <div> <table class=MsoTableLightListAccent5 border=1 cellspacing=0 cellpadding=0 width="40%" style='width:40.24%;border-collapse:collapse;border:none'> <tr> <td width="100%" colspan=2 valign=top style='width:100.0%;border:solid #4BACC6 1.0pt; border-bottom:none;background:#4BACC6;padding:0cm 5.4pt 0cm 5.4pt'> <p class=MsoNormal>VCORE Specification</p> </td> </tr> <tr> <td width="62%" valign=top style='width:62.16%;border:solid #4BACC6 1.0pt; border-right:solid #009EB8 1.0pt;padding:0cm 5.4pt 0cm 5.4pt'> <p class=MsoNormal>Input Voltage</p> </td> <td width="37%" valign=top style='width:37.84%;border:solid #4BACC6 1.0pt; border-left:none;padding:0cm 5.4pt 0cm 5.4pt'> <p class=MsoNormal>10.8V to 13.2V</p> </td> </tr> <tr> <td width="62%" valign=top style='width:62.16%;border-top:none;border-left: solid #4BACC6 1.0pt;border-bottom:none;border-right:solid #009EB8 1.0pt; padding:0cm 5.4pt 0cm 5.4pt'> <p class=MsoNormal>Number of Phases</p> </td> <td width="37%" valign=top style='width:37.84%;border:none;border-right:solid #4BACC6 1.0pt; padding:0cm 5.4pt 0cm 5.4pt'> <p class=MsoNormal>3</p> </td> </tr> <tr> <td width="62%" valign=top style='width:62.16%;border:solid #4BACC6 1.0pt; border-right:solid #009EB8 1.0pt;padding:0cm 5.4pt 0cm 5.4pt'> <p class=MsoNormal>Vboot</p> </td> <td width="37%" valign=top style='width:37.84%;border:solid #4BACC6 1.0pt; border-left:none;padding:0cm 5.4pt 0cm 5.4pt'> <p class=MsoNormal>1.7V</p> </td> </tr> <tr> <td width="62%" valign=top style='width:62.16%;border-top:none;border-left: solid #4BACC6 1.0pt;border-bottom:none;border-right:solid #009EB8 1.0pt; padding:0cm 5.4pt 0cm 5.4pt'> <p class=MsoNormal>VDAC(MAX)</p> </td> <td width="37%" valign=top style='width:37.84%;border:none;border-right:solid #4BACC6 1.0pt; padding:0cm 5.4pt 0cm 5.4pt'> <p class=MsoNormal>1.8V</p> </td> </tr> <tr> <td width="62%" valign=top style='width:62.16%;border:solid #4BACC6 1.0pt; border-right:solid #009EB8 1.0pt;padding:0cm 5.4pt 0cm 5.4pt'> <p class=MsoNormal>ICCMAX</p> </td> <td width="37%" valign=top style='width:37.84%;border:solid #4BACC6 1.0pt; border-left:none;padding:0cm 5.4pt 0cm 5.4pt'> <p class=MsoNormal>90A</p> </td> </tr> <tr> <td width="62%" valign=top style='width:62.16%;border-top:none;border-left: solid #4BACC6 1.0pt;border-bottom:none;border-right:solid #009EB8 1.0pt; padding:0cm 5.4pt 0cm 5.4pt'> <p class=MsoNormal>ICC-DY</p> </td> <td width="37%" valign=top style='width:37.84%;border:none;border-right:solid #4BACC6 1.0pt; padding:0cm 5.4pt 0cm 5.4pt'> <p class=MsoNormal>60A</p> </td> </tr> <tr> <td width="62%" valign=top style='width:62.16%;border:solid #4BACC6 1.0pt; border-right:solid #009EB8 1.0pt;padding:0cm 5.4pt 0cm 5.4pt'> <p class=MsoNormal>ICC-TDC</p> </td> <td width="37%" valign=top style='width:37.84%;border:solid #4BACC6 1.0pt; border-left:none;padding:0cm 5.4pt 0cm 5.4pt'> <p class=MsoNormal>55A</p> </td> </tr> <tr> <td width="62%" valign=top style='width:62.16%;border-top:none;border-left: solid #4BACC6 1.0pt;border-bottom:none;border-right:solid #009EB8 1.0pt; padding:0cm 5.4pt 0cm 5.4pt'> <p class=MsoNormal>Load Line</p> </td> <td width="37%" valign=top style='width:37.84%;border:none;border-right:solid #4BACC6 1.0pt; padding:0cm 5.4pt 0cm 5.4pt'> <p class=MsoNormal>1.5mΩ</p> </td> </tr> <tr> <td width="62%" valign=top style='width:62.16%;border:solid #4BACC6 1.0pt; border-right:solid #009EB8 1.0pt;padding:0cm 5.4pt 0cm 5.4pt'> <p class=MsoNormal>Fast Slew Rate</p> </td> <td width="37%" valign=top style='width:37.84%;border:solid #4BACC6 1.0pt; border-left:none;padding:0cm 5.4pt 0cm 5.4pt'> <p class=MsoNormal>12.5mV/μs</p> </td> </tr> <tr style='height:13.5pt'> <td width="62%" valign=top style='width:62.16%;border-top:none;border-left: solid #4BACC6 1.0pt;border-bottom:solid #4BACC6 1.0pt;border-right:solid #009EB8 1.0pt; padding:0cm 5.4pt 0cm 5.4pt;height:13.5pt'> <p class=MsoNormal>Max Switching Frequency</p> </td> <td width="37%" valign=top style='width:37.84%;border-top:none;border-left: none;border-bottom:solid #4BACC6 1.0pt;border-right:solid #4BACC6 1.0pt; padding:0cm 5.4pt 0cm 5.4pt;height:13.5pt'> <p class=MsoNormal>300kHz</p> </td> </tr> </table> </div> <p>In Shark Bay VRTB Guideline for desktop platform, the requirements of the output filter are as follows:</p> <p>Output Inductor: 360nH/0.72mΩ <br> Output Bulk Capacitor: 560μF/2.5V/5mΩ(max) 4 to 5pcs <br> Output Ceramic Capacitor: 22μF/0805 (18pcs max sites on top side) <br> <br> </p> <p>Step 1 : Determine the Parameters of Inductor</p> <p>Determine inductor value. <br> Output inductor: 360nH/0.72mΩ <br> Determine DCR temperature coefficient TC<sub>DCR</sub>. <br> TC<sub>DCR</sub> = 3930ppm <br> Therefore, the inductor DCR value with temperature effect can be calculated by using (2). The following calculation result gives an example of the DCR value at 60°C. </p> <p class=MsoNormal><a class="fancybox" href="/content/dam/richtek-eds/resources/application-notes/an026/html-images-en/image012_en.jpg" ><img width=365 height=33 id="圖片 21" src="/content/dam/richtek-eds/resources/application-notes/an026/html-images-en/image012_en.jpg" alt="Technical Document Image Preview"></a><br> <br> </p> <p>Step 2 : Determine NTC Parameter for Thermal Compensation</p> <p>Using NCP15WL104J03RC as a NTC thermistor, the resistance is 100kΩ and the β value is 4485. By using (6), the NTC resistance at different temperature can be calculated. When a NTC thermistor operates at 60°C, the resistance can then be calculated as follows:</p> <p class=MsoNormal><a class="fancybox" href="/content/dam/richtek-eds/resources/application-notes/an026/html-images-en/image013_en.jpg" ><img width=300 height=35 id="圖片 22" src="/content/dam/richtek-eds/resources/application-notes/an026/html-images-en/image013_en.jpg" alt="Technical Document Image Preview"></a><br> <br> </p> <p>Step 3 : Design DCR Current Sensing Network and R<sub>x,</sub> R<sub>s</sub> and R<sub>sum</sub> Values</p> <p>DCR current sensing capacitor C<sub>x</sub> and the resistance of R<sub>X</sub> and RS can be determined from the application note of DCR Current Sensing Topology. <br> C<sub>x</sub> = 1μF, R<sub>s</sub> = 3.41kΩ, and R<sub>x</sub> = 590Ω <br> In RT8893, the ratio between R<sub>sum</sub> and (R<sub>x</sub>+R<sub>s</sub>) must set as 4 for the proper operation. <br> R<sub>sum</sub> = 4&#8226;(R<sub>x</sub>+R<sub>s</sub>) = 16kΩ <br> <br> </p> <p>Step 4 : Design R<sub>sum</sub> Resistor Network</p> <p>Set three temperature points for thermal compensation. <br> Choose (TH, TR,TL) = (100, 60, 20) <br> For example, the R<sub>sum</sub> value at 60°C can be obtained from (7): </p> <p class=MsoNormal><a class="fancybox" href="/content/dam/richtek-eds/resources/application-notes/an026/html-images-en/image014_en.jpg" ><img width=372 height=41 id="圖片 17" src="/content/dam/richtek-eds/resources/application-notes/an026/html-images-en/image014_en.jpg" alt="Technical Document Image Preview"></a></p> <p>Therefore, the parameters α<sub>1</sub>, α<sub>2</sub>, and K<sub>R</sub> can then be calculated as follows:</p> <p><a class="fancybox" href="/content/dam/richtek-eds/resources/application-notes/an026/html-images-en/image015_en.jpg" ><img width=405 height=171 id="圖片 19" src="/content/dam/richtek-eds/resources/application-notes/an026/html-images-en/image015_en.jpg" alt="Technical Document Image Preview"></a></p> <p class=MsoNormal>Use (9), (10), and (11), the R<sub>sump</sub>, R<sub>sums2</sub>, and R<sub>sums1</sub> can be found accordingly.</p> <p class=MsoNormal><a class="fancybox" href="/content/dam/richtek-eds/resources/application-notes/an026/html-images-en/image016_en.jpg" ><img width=386 height=125 id="圖片 24" src="/content/dam/richtek-eds/resources/application-notes/an026/html-images-en/image016_en.jpg" alt="Technical Document Image Preview"></a></p> <p class=MsoNormal><br> <br> </p> <h2 id="__Bookmark__5">5. Experiment Result</h2> <p>Figure 5 shows the DCLL and DIMON reporting with DCR temperature compensation. From the experiment results, the DCLL and DIMON reporting are both inside the tolerance band. However, without DCR temperature compensation, the overestimated DIMON reporting result in the heavy load condition will cause DCLL to violate the load line specs as shown in Figure 6. </p> <p class=MsoNormal><a class="fancybox" href="/content/dam/richtek-eds/resources/application-notes/an026/html-images-en/image017_en.gif" ><img width=415 height=262 id="圖片 50" src="/content/dam/richtek-eds/resources/application-notes/an026/html-images-en/image017_en.gif" alt="Technical Document Image Preview"></a></p> <p class=MsoNormal>(a) DCLL </p> <p class=MsoNormal><a class="fancybox" href="/content/dam/richtek-eds/resources/application-notes/an026/html-images-en/image018_en.jpg" ><img width=399 height=250 id="圖片 51" src="/content/dam/richtek-eds/resources/application-notes/an026/html-images-en/image018_en.jpg" alt="Technical Document Image Preview"></a></p> <p class=MsoNormal>(b)DIMON reporting <br> Figure 5. DCLL and DIMON reporting results with DCR temperature compensation </p> <p class=MsoNormal><a class="fancybox" href="/content/dam/richtek-eds/resources/application-notes/an026/html-images-en/image019_en.jpg" ><img width=407 height=255 id="圖片 52" src="/content/dam/richtek-eds/resources/application-notes/an026/html-images-en/image019_en.jpg" alt="Technical Document Image Preview"></a></p> <p class=MsoNormal>(a) DCLL </p> <p class=MsoNormal><a class="fancybox" href="/content/dam/richtek-eds/resources/application-notes/an026/html-images-en/image020_en.jpg" ><img width=410 height=257 id="圖片 53" src="/content/dam/richtek-eds/resources/application-notes/an026/html-images-en/image020_en.jpg" alt="Technical Document Image Preview"></a></p> <p class=MsoNormal>(b)DIMON reporting <br> Figure 6. DCLL and DIMON reporting results without DCR temperature compensation <br> <br> </p> <h2 id="__Bookmark__6">6. Conclusion</h2> <p>This application note provided the implementation methods and useful design equations for DCR temperature compensation. With proper design procedure, it can effectively mitigate the temperature variation on DCR values and provide correct current information for DCR current sensing applications.</p> <p class=MsoNormal><br> <br> </p> <h2 id="__Bookmark__7">7. Reference</h2> <p>[1] Richtek, RT8884B datasheet. <br> [2] Richtek, RT8893 datasheet. <br> [3] Intel, VR12.5 Pulse Width Modulation (PWM) Specification <br> [4] Richtek, DCR Current Sensing Topology Application Note. </p> <p class=MsoNormal><br> <br> </p> <h2 id="__Bookmark__8">Appendix I Derivation of DCR Temperature Compensation Network</h2> <p>Substitute three temperature points (TL, TR, TH) into (8), (12) to (14) can be obtained. Therefore, (15) and (16) can be respectively obtained from (12)–(13) and (13)–(14).</p> <p><a class="fancybox" href="/content/dam/richtek-eds/resources/application-notes/an026/html-images-en/image021_en.jpg" ><img width=506 height=311 id="圖片 25" src="/content/dam/richtek-eds/resources/application-notes/an026/html-images-en/image021_en.jpg" alt="Technical Document Image Preview"></a></p> <p>Define k<sub>R</sub>=R<sub>sump</sub>+R<sub>sums2,</sub> (15) and (16) can be further expressed as (17) and (18).</p> <p><a class="fancybox" href="/content/dam/richtek-eds/resources/application-notes/an026/html-images-en/image022_en.jpg" ><img width=619 height=272 id="圖片 26" src="/content/dam/richtek-eds/resources/application-notes/an026/html-images-en/image022_en.jpg" alt="Technical Document Image Preview"></a></p> <p class=MsoNormal><a class="fancybox" href="/content/dam/richtek-eds/resources/application-notes/an026/html-images-en/image023_en.jpg" ><img width=631 height=274 id="圖片 27" src="/content/dam/richtek-eds/resources/application-notes/an026/html-images-en/image023_en.jpg" alt="Technical Document Image Preview"></a></p> <p>Equation (19) can be derived by (18)/(17).</p> <p class=MsoNormal><a class="fancybox" href="/content/dam/richtek-eds/resources/application-notes/an026/html-images-en/image024_en.jpg" ><img width=469 height=170 id="圖片 28" src="/content/dam/richtek-eds/resources/application-notes/an026/html-images-en/image024_en.jpg" alt="Technical Document Image Preview"></a></p> <p>From (18), the Rsump can be found as shown in (20). </p> <p class=MsoNormal><a class="fancybox" href="/content/dam/richtek-eds/resources/application-notes/an026/html-images-en/image025_en.jpg" ><img width=471 height=61 id="圖片 29" src="/content/dam/richtek-eds/resources/application-notes/an026/html-images-en/image025_en.jpg" alt="Technical Document Image Preview"></a></p> <p>Then, the Rsums2 can be obtained as (21). </p> <p><a class="fancybox" href="/content/dam/richtek-eds/resources/application-notes/an026/html-images-en/image026_en.jpg" ><img width=467 height=71 id="圖片 30" src="/content/dam/richtek-eds/resources/application-notes/an026/html-images-en/image026_en.jpg" alt="Technical Document Image Preview"></a></p> <p>Therefore, the Rsums1 can be derived as (22).</p> <p class=MsoNormal><a class="fancybox" href="/content/dam/richtek-eds/resources/application-notes/an026/html-images-en/image027_en.jpg" ><img width=466 height=113 id="圖片 31" src="/content/dam/richtek-eds/resources/application-notes/an026/html-images-en/image027_en.jpg" alt="Technical Document Image Preview"></a></p> <p class=MsoNormal><br> <br> </p> <div> <table border="1" cellspacing="0" cellpadding="0" style="width: 637.5pt; border-collapse: collapse; border: medium none;" class="3-51"> <tbody> <tr style="height: 17pt;"> <td style="border-width: 1pt 1px 1px 1pt; border-style: solid; border-color: #009eb8; background-color: #009eb8; background-image: url(e); background-repeat: repeat; background-attachment: scroll; background-clip: border-box; background-origin: padding-box; background-size: auto auto; padding-right: 5pt; padding-left: 5pt; height: 17pt;" colspan="2"> <span style="color: #ffffff;">Next Steps</span> </td> </tr> <tr style="height: 17pt;"> <td style="border-width: 1pt 1px 1px 1pt; border-style: solid; border-color: #009eb8; background-color: #ffffff; background-image: url(e); background-repeat: repeat; background-attachment: scroll; background-clip: border-box; background-origin: padding-box; background-size: auto auto; padding-right: 5pt; padding-left: 5pt; height: 17pt;"> Richtek Newsletter </td> <td style="border-width: 1pt 1px 1px 1pt; border-style: solid; border-color: #009eb8; background-color: #ffffff; background-image: url(e); background-repeat: repeat; background-attachment: scroll; background-clip: border-box; background-origin: padding-box; background-size: auto auto; padding-right: 5pt; padding-left: 5pt; height: 17pt;"> <a class="link" href="http://www.richtek.com/My%20Richtek/Newsletters" target="_blank">Subscribe Richtek Newsletter</a> </td> </tr> <tr style="height: 17pt;"> <td style="border-width: 1pt 1px 1px 1pt; border-style: solid; border-color: #009eb8; background-color: #ffffff; background-image: url(e); background-repeat: repeat; background-attachment: scroll; background-clip: border-box; background-origin: padding-box; background-size: auto auto; padding-right: 5pt; padding-left: 5pt; height: 17pt;"> Download </td> <td style="border-width: 1pt 1px 1px 1pt; border-style: solid; border-color: #009eb8; background-color: #ffffff; background-image: url(e); background-repeat: repeat; background-attachment: scroll; background-clip: border-box; background-origin: padding-box; background-size: auto auto; padding-right: 5pt; padding-left: 5pt; height: 17pt;"> <a class="link" href="~/media/AN%20PDF/AN026_EN.ashx">Download PDF</a> </td> </tr> </tbody> </table> </div> <p class=MsoNormal><br> <br> </p> </div>
false

i18n(article-attachment.related-product-list.title)

_ATTACHMENT_HIDDEN_FIELD_

related-products


_ATTACHMENT_HIDDEN_FIELD_


applicationNoteArticle
application-note
12
true
relatedProductList
left
btnAllApplicationNote2
text-with-icon
secondary
i18n(button-item.all-application-note.button-label)
i18n(button-item.all-application-note.button-link)
_self
false
100
100
100
100