8
8
8
4
32
32
32
0
  • content-section
rt-light-blue-500
techInsightSubtitle
rt-dark-900
headline-3
false
false
techInsightTitle
12
12
12
12
rt-dark-300
techInsightInfo
32
32
32
32
<link href="/css/www-style.css" rel="stylesheet"><link href="/css/bootstrap.css" rel="stylesheet"><link href="/css/newsletter.css" rel="stylesheet"><link href="/css/alfontawesome-all.css" rel="stylesheet"><div class="key-container pb-5"><div class="cus-content"><div class="row no-gutters "><div class="col-md-12 text-center"><a href="https://www.youtube.com/watch?v=BW4rhehAmWo&&utm_source=Newsletter&utm_medium=RTWWW&utm_campaign=Issue53EN&sc_lang=en" target="_blank"><img class="img-center " style="max-width:600px;" alt="80V Hot Swap Controller with Multi-Level Precision OCP" src="/content/dam/richtek-eds/resources/tech-insights/news/newsletter-issue-53/html-images/en_I53_design_video_EN.gif"></a></div><div class="col-md-12 mb-40"><p>As power demands in data centers continue to escalate, modular systems such as servers and power distribution boards increasingly rely on hot swap capability to improve scalability while maintaining high operational efficiency.</p><p>AI workloads, with their wide and highly dynamic current surges, present a tough challenge for hot swap controllers. Traditional hot swap controllers with only a single level of overcurrent protection (OCP) often struggle to differentiate between genuine faults and normal transient peaks, leading to false shutdowns or missed faults that threaten system reliability.</p><p>The Richtek<a href="https://www.richtek.com/RedirectToProduct?specid=RTQ1954&utm_source=Newsletter&utm_medium=RTWWW&utm_campaign=Issue53EN&sc_lang=en" target="_blank" style="text-decoration: none; color: #37a6d9;font-size: 1.1rem;"> RTQ1954 </a>80V hot swap controller is designed to meet these demands. Its multi-level OCP architecture precisely identifies short current pulses, repetitive overloads and sustained soft shorts, delivering robust protection for high-power systems with wide dynamic loads.</p></div><div class="col-md-12 "><div class="mb-2"><div class="section-title font-weight-bold mb-30 pb-3">Key Advantages</div></div></div><div class="col-md-12 text-center"><img class="img-center " style="max-width:800px;" alt="80V Hot Swap Controller with Precision Multi-Level Overcurrent" src="/content/dam/richtek-eds/resources/tech-insights/news/newsletter-issue-53/html-images/en_I53_01_2_EN.jpg"></div><div class="col-md-12 mb-40"><ol style="line-height:2;"><li style="list-style-position:outside;"><b>Four-Level OCP</b>:Start-up inrush current protection (OCP1), adjustable steady-state overcurrent protection (OCP2), dynamic pulse current protection (OCP3), and a fast-response circuit breaker (CB) cover all load scenarios.</li><li style="list-style-position:outside;"><b>Non-accumulative Timer</b>: Digital and analog OCP timers prevent accumulative false trips under repetitive high-duty-cycle pulses.</li><li style="list-style-position:outside;"><b>Soft Short Detection</b>:Four adjustable thresholds ensure even high-impedance sustained soft shorts are detected and managed.</li><li style="list-style-position:outside;"><b>Streamlined Thermal Design</b>:Allows steady state system thermal design including external MOSFETs be based on actual DC power rather than elevated fault thresholds, reducing component count and cost.</li></ol></div><div class="col-md-12 mb-40"><p>With CPU/GPU power levels rising rapidly, thermal design for hot swap controllers can be optimized around the average DC load. The<a href="https://www.richtek.com/RedirectToProduct?specid=RTQ1954&utm_source=Newsletter&utm_medium=RTWWW&utm_campaign=Issue53EN&sc_lang=en" target="_blank" style="text-decoration: none; color: #37a6d9;font-size: 1.1rem;"> RTQ1954 </a>complements this by providing comprehensive protection across a wide range of overcurrent conditions, enabling power system designs that combine high performance with robust reliability.</p></div><div class="col-md-12 "><div class="mb-2"><div class="section-title font-weight-bold mb-30 pb-3">Learn More</div></div></div><div class="col-md-12 "><p>Discover how the<a href="https://www.richtek.com/RedirectToProduct?specid=RTQ1954&utm_source=Newsletter&utm_medium=RTWWW&utm_campaign=Issue53EN&sc_lang=en" target="_blank" style="text-decoration: none; color: #37a6d9;font-size: 1.1rem;"> RTQ1954 </a> safeguards an 8.5 kW system against dynamic AI loads while optimizing performance and thermal performance.</p><div class="btn-block pb-4 pt-3"><a href="/content/richtek-eds/en/design-support/application-notes/an092" target="_blank" class="btn-sm btn-primary py-2 px-3">Application Note<i class="fas fa-arrow-right pl-2"></i></a></div><p>For more on NVIDIA AI data center power solutions and the latest industry updates, check these out</p><ul style="line-height:2;"><li><a href="https://developer.nvidia.com/blog/building-the-800-vdc-ecosystem-for-efficient-scalable-ai-factories/?ncid=so-link-262195&linkId=100000386911433" target="_blank" style="text-decoration: none; color: #37a6d9;font-size: 1.1rem;">Building the 800 VDC Ecosystem for Efficient, Scalable AI Factories<i class="fas fa-arrow-right pl-2"></i></a></li><li><a href="https://blogs.nvidia.com/blog/gigawatt-ai-factories-ocp-vera-rubin/" target="_blank" style="text-decoration: none; color: #37a6d9;font-size: 1.1rem;">NVIDIA, Partners Drive Next-Gen Efficient Gigawatt AI Factories in Buildup for Vera Rubin<i class="fas fa-arrow-right pl-2"></i></a></li></ul></div></div></div></div>
true
techInsightContent
36
36
36
24
tech-insight
12
i18n(product-list.feature-product-list.title)
true
rt-dark-900
featureProducts
36
36
36
24
60
60
60
24
64
64
64
64